Netronics Power Supply

Published on 20 August 2023 at 17:32

First of all I didn't know these even existed!

Inspection:

This one was very badly constructed with many cold solder joints with moving wires within the joints readily visible!

Cleanup:

The electrolytics were replaced, note the much smaller physical sizes! All the main wires were replaced and joints properly soldered.

A silicon highly flexable 18 AWG power cable was constructed to connect the ELF to the supply.

Testing:

Testing was then completed using an electronic load:

  • Testing done at no load and with a 2A constant current load
Switch Settings (1/2/3) No Load (volts/ ripple in RMS) 2A Constant Current Load (volts/ ripple in RMS)
L/L/L 8.26 V with 3mV 6.57 V with 152mV
H/L/L 9.55 V with 4mV 7.86 V with 153mV
L/H/L 10.5 V with 4mV 8.72 V with 154mV
L/H/H 12.1 V with 4.5mV 10.45 V with 155mV